Juniper ex4200 factory reset button. I've reset the switch to factory defaults.
Juniper ex4200 factory reset button disco83. . KB10503 : [EX/QFX/ACX] Password recovery procedure [EX] How to revert back to default factory configuration. To troubleshoot a services gateway, you use the Junos OS command-line interface (CLI) and LEDs on the components: Juniper Networks Complete Guide to Juniper Router Reset and Factory Configuration Models: J2320. However, under certain circumstances, the system may To restart the switch from the front panel: From the LCD front panel menu push the Menu button. Note: The default login username is root and the default password is blank. Sometimes administrators working on Junos platform need a juniper factory reset. I forgot to reste the config with the button on the device when I was reracking it. 4R1. That switch is then hooked into my router. I get the attached message when I try to do the root password reset. Members Online • General-Makepeace. You can revert to the default factory configuration by using the Menu button to the right of the LCD on the front panel of the switch or by using the load factory-default configuration command. io to get free access to our entire library of content!Josh's Juniper EX-Series switch he Reverting to the EX Series Switch Factory-Default Configuration Using the load factory- default Command. txt) or read online for free. 1/2. root@%. Here is the two procedures to reset your Juniper SSG ScreenOS device. Hello there, im looking for some ideas about what is happen with my two junipers switches, I don't remember the password so Im trying to follow the root passwor Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the EX4200 switch. Learn how to reset a lost root password for Juniper devices with this step-by-step YouTube tutorial. "Serial" connection type, leave baud rate (Speed) and other settings as default. To troubleshoot a services gateway, you use the Junos OS command-line interface (CLI) and LEDs on the components: By default, pressing and holding the Reset Config button for 15 seconds or more—until the Status LED is solid amber — deletes all configurations on the device, including the backup configurations and rescue configuration, and loads and commits the factory configuration. However after boot -s it wants root password:. Chassis LED reports "SPD ALARM 01, and when I cycle the menu with the enter button, also shows DPX ALARM 01, POE ALARM 01, and ADM ALARM 01. The first method (if you have the password for your device) and serial connection to your device, you can do a software reset as followed. Expand search. This is the first configuration of the switch and it is loaded when the switch is first installed and EX3200 および EX4200 イーサネット スイッチ ハー Juniper and Juniper’s licensors, respectively, retain ownership of all right, title, and interest (including copyright) in and to the Software, associated documentation, and all copies of the Software. Configuration is corrupted. 0 Recommend. 1 EX Series switches include a factory default configuration that: On an EX3300 Virtual Chassis, an EX4200 Virtual Chassis, an EX4500 This topic applies only to the J-Web Application package. Sure, I can get access to the machine next week sometime but I'd cpu_reset: Stopping other CPUs SPI stage 1 bootloader (Build time: May 3 2016 - 23:48:30) early_board_init: Board type: SRX_300 U-Boot 2013. Use the 'load override' command to recall your previous configuration. Error: Cannot start EZSetup, system is not in factory configuration mode. Solution. ly/1V0AQ1WThis video focuses on restoring a junos device and resetting to factory defaults. From the "loader>" prompt type "install file:///<name_of_image. Place the image on a USB flash drive, reboot the switch and interrupt the boot process. ? For example, I pushed the button on the panel. 100311 (0x02) Now want to connect to the web interface but I just can get on to it. 5 %âãÏÓ 9 0 obj 5029 endobj 4 0 obj /Length 9 0 R /Filter /FlateDecode >> stream xÚ\IÏ Éq½ç¯¨ó]Î} {æà› > >µ5 Œ 4ÿÿ [fVw“lÊ This topic applies only to the J-Web Application package. Another is not implementing I did same method Even though they are same device(ex3300), why does this one not implement factory-reset. conf mgd: warning: activating factory configuration mgd: Running FIPS Self-tests veriexec: no fingerprint for file='/sbin In the event of software failure, a rescue configuration helps to load a known working configuration. 6 (Nov 22 2009 - 07:01:21) Board: EX2200-48P-4G 4. Hướng dẫn Reset Switch Juniper EX2200 về Cấu hình mặc định Tổng quan. to perform a You can remove or replace a member switch in a Virtual Chassis without disrupting network service on the other member switches. you should do this: http://www. Posted 02-11-2011 14:42 to start clean with the device (it's just been moved from an site to a new one). I had the same problem but my EX2300-C was not in a boot loop, not able to even get to the loader, what I end up doing was opening the unit, there is a mini usb port inside that connected directly to the internal memory, since those partitions are freeBSD, i was able to mount those with a virtual machine, and edit the files on both partitions. Wait about 2 minutes while the Juniper SRX210 restores to the factory default settings. Last week member 3, which is an EX4200, seemed to reset all of its interfaces briefly which of course caused a short network outage. Make If you have a Juniper switch that is up for sale or being scrapped, it should be factory reset. With this guide, your Juniper EX4000 factory reset should be a smooth and straightforward process, restoring your device to its original, out-of-the-box state. This is linked to post: EX4200 Boot Loop | Junos OS (juniper. I can enter single user mode by interrupting startup and entering 'boot -s', but nothing I have tried (factory reset and zeroize) makes any difference. Created 2019-07-30. Recover password. warning: activating factory configuration. Caution : If you use the Reset Config button to reset the device to its factory default configuration, all the configuration files, including the rescue Hello. We hope this guide has been helpful in understanding the process of how to resetJuniper EX4000 switches. Below is a sample output: Runt he reboot command when asked and once it is finished you will be fully upgraded. Hello, I factory reset a Juniper EX4300-24T switch, did the EZSetup via J-web without any hickups, but I am unable to log into the swtich. 16 EPLD: Version 04. Step 3. I work for an electronics recycler, and today I'm resetting / testing around 100 of these units for resale. The following menu options are available through the LCD: We have a virtual chassis consisting of EX4500 and EX4200 devices. Junos OS 14. juniper. Hey guys. I bought a used juniper ex4200. Steps for factory defaulting the EX switch: Login as root from console. If you forget the root password, you can use the password recovery procedure to reset the root password. But I can't find the command in my Juniper QFX3000-G and QFX3000-M Qfabric systems have reached end-of-support (EOS). Junos osfor exseries ethernetswitches (354 pages) Press the Factory Reset/Mode button for 10 more seconds. I held the front button on the front for about 30 seconds. KB20643 : [EX] Performing and resolving any common issues during Format Install on legacy EX platforms. Being second hand it is s Factory reset EX4200. Reverting to the Default Factory Configuration for the EX Series Switch - Technical Documentation - Support - Juniper Networks - Free download as PDF File (. 330. I am trying to reset the root password but I can't figure it out. set system commit factory-settings reset-virtual-chassis-configuration; set system commit factory-setting reset-chassis-lcd-menu; When an additional configuration is merged with this factory-default configuration and committed just once, the system commit factory-settings continues to remain in the configuration and causes the above issue in Hi guys,This is linked to post: EX4200 Boot Loop | Junos OS (juniper. 1. Any ideas? Thanks The EX Switch will boot and get an IP address in the offer packet, DHCP will send the TFTP server IP address (Option 150) and boot file name. 4. I have a server which gets its IP address from a DHCP server built into my router, hooked up to a juniper EX4200 switch with factory reset configuration. U-Boot 1. Hi all I'm trying to reset the password on a Juniper EX2200 switch which was configured by someone who has left the organization. Start here to evaluate, install, or use the Juniper Networks® EX4200 Ethernet Switch. Factory reset EX4200. Thank You . The Reset Config button is recessed to prevent it from being pressed accidentally; so you need to insert a small probe (for example, a straightened paper clip) to press the EX3200 and Some early variants of EX3200 and EX4200 switches for which the Juniper Networks EX4200 model number on the label next to the protective earthing terminal is from 750-021 xxx require 10-24x. I have tried to recovery password using standart Password Recovery Procedure. It runs on a continuous loop and resets itself after the zeroize command. Some devices have two console ports: an RJ-45 console port and a Mini-USB Type-B console port. Description. Get your device serial number using the following command (or by reading the label on your device) : get system | i serial. Follow this procedure if you need to revert an access point (AP) to its factory-default settings. If for any reason the current active configuration fails, you can revert to the factory-default configuration. Root password changed to wrong password. [EX] How to revert back to default factory configuration. I have done the Skip to main content. Last Updated 2019 The Reset Config button is recessed to prevent it from being pressed accidentally; so you need to insert a small probe (for example, a straightened paper clip) to press the button. The Reset Config button is recessed to prevent it from being pressed accidentally; so you need to insert a small probe (for example, a straightened Each EX Series switch is programmed with a factory-default configuration that contains the values set for each configuration parameter when a switch is shipped. You can recover Hello, I factory reset a Juniper EX4300-24T switch, did the EZSetup via J-web without any hickups, but I am unable to log into the swtich. The LCD panel displays a variety of information about the switch and also provides a menu to perform basic operations such as initial setup and reboot. ; Note : On EX3200, EX3300. Log in. You may use it and default the switch. I replaced the switch with a spare but need to 'wipe' this one clean (or do a factory reset). The LCD panel on the front panel of the EX4300 switch shows two lines of text, each with a maximum of 16 characters. I just did a detailed reply to Paul about this, but my posts needs moderation first before being seen %PDF-1. RESET CONFIG Button. thank you I bought a SRX240 to start getting familiar with Juniper. Once upgraded you will be able to run ezSetup after one more factory reset. If it is a used but "new to you" switch, you may be able to factory reset it via Ask questions and share experiences with Juniper Connected Security. I came across a Cisco automation script to reset Cisco devices and modified it to fit all Cisco devices. 0R2, and 10. Open menu Open navigation Go to Reddit Home. Posted 12-09-2021 10:49. The config was not wiped before it was sold, thus I do not know the username/login to access the device. 180. The default configuration file sets values for system parameters such as syslog and commit, configures PoE and Ethernet-switching on all interfaces, and enables the LLDP (Link Layer %PDF-1. Need to reset other equipment, see more TeleTraders reset guides below, or give Note : The Reset Config button is available only on the SRX Branch. No need to remember the rollback number; if you saved a configuration, you can use it anytime when needed. I've had to reset a few SRX and EX Description . How to factory reset instructions tutorial guide. 181. The Reset Config button is recessed to prevent it from being pressed accidentally; so you need to insert a small probe (for example, a straightened JUNIPER SRX Device Factoty Reset. I had this happen to a few EX4200 from factory. ADMIN MOD EX4200-48P factory root password not working during ezsetup . pdf), Text File (. The switch transitions into initial setup mode, the console displays committing ezsetup config, and the Link/Activity LED on the RJ-45 I want to factory default a EX4200 by cli through console port, but it comes out with below error and If you don't mind the logs, etc. I am trying to set up a home network. See Table 1 for the configurable options and their default settings. The switch transitions into initial setup mode, the console displays committing ezsetup config, and the Link The following steps provide a method for factory defaulting the EX switch, from the console port, to run the EZsetup application. I plugged in my laptop into port 0 as described in this Juniper article. 163 Switch Juniper EX4200 Product Overview. ; To exit the menu without rebooting the switch, press the Menu button again. Output : root password reset. {primary:node0} root> Any ideas please, the unit is sitting next to me and have console cable attached. I don't know root password and can't access to cli. then committed and rebooted, but I still don't get a password prompt. 5). ; When the MAIN MENU (Maintenance menu) appears, press the Enter button. Discuss Advanced Threat Protection, SecIntel, Secure Analytics, Secure Connect, Security Director, and all things related to Juniper security technologies. Power on the Juniper SRX210 by plugging it to the power adapter. Or if you do have another account that you can get into and save the config (only save minus the root password config), then reset to factory defaults which will prompt you for login and you can then load the save config file using the load merge option. More. 162. Plug power into device and if a power button exists, turn it on. Hi all, do anyone know how to factory reset a Ex series switch, include all configuration, vlan data, etc, thanks! Log in to ask questions, share your expertise, or stay connected to content you value. NOTE: Running "load factory-default" from configuration mode does not allow you to run EZsetup. 0R1, 10. How to recover Junos on QFX5100/EX4600. I know that is a command "delete system commit factory-settings" mentioned in juniper KB11159. Knowledge Base Back. When i go through the password recovery process this is what happens: Each EX Series switch is programmed with a factory default configuration that contains the values set for each configuration parameter when the switch is shipped. Archived User. Juniper EX4200. EX4200. To see EOS details, visit QFX Series Hardware Dates & Milestones. It appears that the previous IT Manager tried an upgrade and ran out of space. If Junos OS software is damaged on your device, the emergency boot device helps you to recover the software. I went through the menu and clicked ezconfig and it tells me to connect to port 0. So I attempted a factory default reset both via console and front panel button press sequence and each time get something like: file: /config/juniper. If nothing works out after following above steps, there is mode / factory reset button to reset your switch to factory defult. Printable View « Go BackGo Back Juniper Networks KB15725 : [SRX] Getting Started - Factory Reset KB11041 : Factory defaulting the EX-series switch to run EZsetup from console KB17565 : [SRX] Root password recovery not working with Junos release versions 10. To load the factory default : # load factort-default. EX4200 and Each EX Series switch is programmed with a factory default configuration that contains the values set for each configuration parameter when the switch is shipped. If you want just load factory default without erasing rollback configuration and user data. I have tried the reset button on the front panel, holding it for 15+ seconds, and the status LED never turns amber. However, under certain circumstances, the system may Juniper EX4200-48px, Management Ethernet Link Down alarm . Hello everyone. I can ping the server but when I try to SSH to the server I get kex_exchange_identification: read: Connection reset by peer Need to erase the configuration or reset to factory defaults. Using a pin or paperclip, press and hold the RESET CONFIG button for 15 seconds. Home; Knowledge; Quick Links. At this point you can log in as the root user without a password. When the mixed The front panel of an EX3400 switch consists of the following components: Find many great new & used options and get the best deals for Juniper Networks EX4200-48T 48 Port 8 PoE Network Switch Rev C - FACTORY RESET! at the best online prices at eBay! Free shipping for many products! After pressing the reset button, ensure to reboot the device according to the instructions provided in the following documentation: [SRX] Getting Started - Factory Reset Following these steps should successfully resolve the issue with the reset button on the device. The EX4200 is well-suited to campuses as well as 1 Gigabit Ethernet (1GbE) access environments in the data center. 1R1 Use the procedures described in this topic to set up Virtual Chassis ports (VCPs) to connect two switches together in an EX Series or a QFX Series Virtual Chassis. After completing the installation and basic configuration procedures covered in this guide, refer to the Junos OS documentation for information about further software configuration. Using the Reset Config Button. Juniper reset has quite a few options to meet this Thinking that I was not that far into the configuration, and I was mostly just messing around with configuration, I figured it was easier to factory reset the switch. r/Juniper A chip A close button. Maintenance -> factory reset -> no response;; pls contact me experts. Do sự khác biệt về phần cứng vật lý, quy trình đặt lại mặc định nhà máy của EX2200 khác với reset switch Juniper EX3200 và EX4200. Junos OS Commands: Enter the necessary Junos OS commands through the Command-Line Interface (CLI) to initiate a software-based factory reset. You can configure and manage the device using either port. Note : The Reset Config button is available only on the SRX Branch. tgz". 1. 9. factory default reset. This topic applies only to the J-Web Application package. This article describes the method to force an EX device into loader mode while booting up. I hope this helps anyone who is having a similar issue. We also explain the Juniper default user name and password, along with how to change the default password. Juniper Support Portal. and Security Appliances manufactured by Juniper. You can use the Reset Config button on the front panel of the SRX device to reset the device to its factory default configuration. Bài viết này cung cấp thông tin về các phương pháp để reset switch Juniper EX2200 về cấu hình mặc định của nhà máy. I think the issue is that the switch is operating as a non master in a vc system. Several EX-series devices support the Mixed mode of the virtual chassis. net) I got Complete instructions, step by step how to factory reset a Juniper EX switch. From local unix shell: cd /config/vchassis/ rm * Then reboot. This article describes the issue of the request system zeroize not removing the virtual chassis from the mixed mode. Any help with next steps would be appreciated. exclusive {master:0}[edit] error: No factory configuration available . request system zeroize (Junos OS) | Junos OS | Juniper Networks load factory-default delete system commit factory-settings set root-authentication plain-text-password juniper1 as password Then commit (it won't commit without a password) Subject: Juniper EX4200 remove vc and revert to default Hello. When customers receive a new EX/QFX switch and power it on, it requests a login name and password. It just runs through a boot process and then reboots, landing me back at a login prompt. You can use the Reset Config button on the front panel of the SRX firewall device to reset the device to its factory default configuration. You can use the load factory-default command to restore the factory default configuration on a Virtual Chassis without removing anything needed to keep the Virtual Chassis working. Description . The default configuration file sets values for system parameters such as syslog and commit, configures Ethernet switching on all interfaces, enables IGMP snooping, and enables the LLDP and RSTP protocols. ; Select the SYSTEM REBOOT option and press the Enter button. Get app Get the Reddit app Log In Log in to Reddit. Configuring Junos OS on the EX3400 | Juniper Networks Since there are no configuration files in the /config directory the switch boots to a factory default configuration. Note: EX switches may not be able to boot up normally due to a power outage or other failure. Move or Remove the current configuration files You can change the management mode or configure a guard band setting for a standalone switch or for all members of an EX3300 Virtual Chassis, an EX4200 Virtual Chassis, an EX4300 Virtual Chassis, or a mixed EX4200 and EX4500 Virtual Chassis that supports PoE, or a mixed EX4300 and EX4600 Virtual Chassis that supports PoE. Reset password . After completing the installation and basic configuration procedures covered in this guide, refer to the Mist Wired Assurance documentation to learn more about configuration and management of the switch. We assume you know nothing and show you which cable you need, what software you need and what commands to run: Connect your computer to your Juniper switches (Background, never dealt with Juniper, trying to learn) I just bought a Juniper Ex4200 off ebay. You might not have to do any additional configuration if the default settings work for you. have attempted to factory reset an SRX100B, but the config on reboot is persisting and for example the prompt displays HA node. Each EX Series switch is programmed with a factory-default configuration that contains the values set for each configuration parameter when a switch is shipped. Default Factory Configuration contains the basic configuration settings. The standard procedure is to re-format and install from loader by following the instructions provided in KB20643 . Hi guys, This is linked to post 3. I opened a ticket with JTAC but they don't seem to have many answers. Question Hello all, I bought an EX4200 Each EX-series switch is programmed with a factory default configuration that contains the values set for each configuration parameter when a switch is shipped. People also viewed. The button is recessed to prevent it from being pressed accidentally. Ricky-----Ricky Garner----- I have a Juniper EX4200 series 8PoE that was donated to me as a lab asset. #set system root-auth plain-text-password |( then press enter & give the password fopr the root account ) # commit . For some reason I found it tough to find Juniper's technical documentation on the cli. If you have a Juniper switch that is up for sale or being scrapped, it should be factory reset. Modification History 2024-03-27 : Article Created Related Information OneDrive link to config files: http://bit. 1R3. Move or Remove the current configuration files Having performed a software reinstall multiple times on different firmware versions, the switch makes it to a login prompt, but reboots only a few seconds after. Boot into single-user mode Prsnt XXXXXXXXXXXX ex4200-24f 128 Master* N VC Member ID for next new member: 1 (FPC 1 There are two ways to connect and configure an EX4400 switch: one method is through the console by using the CLI and the other is by using the J-Web interface. 5 %âãÏÓ 9 0 obj 5027 endobj 4 0 obj /Length 9 0 R /Filter /FlateDecode >> stream xÚ\IÏ Éq½ç¯¨ó]Î} {æà› > >µ5 Œ 4ÿÿ [fVw“lÊ To restart the switch from the front panel: From the LCD front panel menu push the Menu button. Download 330 pages 32. Misspelled the root password. Hardware Reset: Like many brands across and types of networking Use this command to remove all configuration information on the Routing Engines and reset all key values on the device where you run the command. The following steps provide a method for factory defaulting the EX switch, from the console port, to run the EZsetup application. Is it possible to perform a factory reset of an EX2200-C without using the CLI or web interface? Perhaps via the mode After pressing the reset button, ensure to reboot the device according to the instructions provided in the following documentation: [SRX] Getting Started - Factory Reset Following these steps should successfully resolve the issue with the reset button on the device. EX4200 and 4 Reverting to the Factory-Default Configuration Using the Factory Reset/Mode Button on Ex2300, Ex3400, and Ex4300-48Mp Switches; Download this manual; EX2300 Switch Hardware Guide EX3200 and Some early variants of EX3200 and EX4200 switches for which the Juniper Networks EX4200 model number on the label next to the protective earthing In case of a failed software installation or a failure after installing Junos OS, such as the CLI not working, you can recover the failed software. Once the EX Switch gets this information from DHCP it will try to fetch the conf file from the TFTP server as shown below Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the EX4400 switch. 161. If you press reset button for 15sec, watch the status LED turn amber color. One is implementing factory-reset. I am trying to log into the j-web to enable SSH per the instructions. SRX の前面パネルにあるReset Config ボタンを使用して、デバイスを工場出荷時の デフォルト設定にリセットすることができます。 Reset Config ボタンは、誤って押されないように凹んでいます。 ①前面パネルのRESET CONFIG ボタンを15秒以上押し続ける Each EX Series switch is programmed with a factory-default configuration that contains the values set for each configuration parameter when a switch is shipped. Hi all, I have used EX2200 (EX2200-48T-4G JUNOS 11. JUNOS 10. Enterprise level hardware is new to me. To connect to the device using a passive port, you must first configure the port as active and then reboot the device. net/techpubs/en_US/release Press the Factory Reset/Mode button for 10 seconds. net Each EX Series switch is programmed with a factory default configuration that contains the values set for each configuration parameter when the switch is shipped. Nothing in this Agreement constitutes a transfer or For EX Series switches that support PoE ports, the factory default configuration enables PoE on the PoE-capable ports, with default settings in effect. We assume you know nothing and show you which cable you need, what software you need and what commands to run: Connect your computer to your Juniper switches Press the Factory Reset/Mode button for 10 more seconds. The default configuration file for an EX2300 switch configures Ethernet switching and storm control on all interfaces, configures Power over Ethernet (PoE) on all interfaces of models that provide PoE, and enables the If you enjoyed this video, be sure to head over to http://techsnips. 25 in. Enter Reverting to the EX Series Switch Factory-Default Configuration Using the load factory- default Command. Article ID KB34866. For first-time Junos EX/QFX users this could be confusing as there is no password information included. Reverting to the I have an EX2200-C that I don't have the password for. The default configuration file for an EX2300 switch configures Ethernet switching and storm control on all interfaces, configures Power over Ethernet (PoE) on all interfaces of models that provide PoE, and enables the 7/22/2019 Juniper Ex4200 Factory Reset. Use the button next to the bottom right corner of the LCD to scroll through the menu. juniper. 1 (Build time: May 03 2016 - 23:48:31) SRX_300 board revision major:1, Ask questions and share experiences about ACX Series, CTP Series, MX Series, PTX Series, SSR Series, JRR Series, and all things routing, including portfolios and protocols. I'm trying to reset the password by rebooting, hitting the space bar and typing "boot -s". Reverting to the Factory-Default Configuration Using the EX Series Switch LCD Panel. Welcome to the Juniper subreddit, a Subreddit dedicated to discussing Routers, Switches and Security Appliances manufactured by Juniper. Attached is the excerpt of the messages log. The script runs safe mode and sets the root password then logs in and zeroises the switch to factory defaults. 01 Kb. . Step 2. This should install and put you at a login prompt. Close search. Post reset, you should be able to access the switch. We would like to show you a description here but the site won’t allow us. Select the appropriate product link to view the instructions for recovering or resetting a password: Most of the links require CSC login access. I've reset the switch to factory defaults. when I reboot it has wiped the interface settings and hostname, but I still get this . however, instead of getting to a prompt type in recovery and begin the password reset procedures. Juniper Ex4200 Configuration Manual The following factory default configuration file is for an EX4200 switch with 24 ports (for models that have more ports, this default configuration file has more. I juniper ex4200 factory reset without passwordlawrence, ma breaking news today juniper ex4200 factory reset without password Navigation mode - The LCD switches to this mode from idle mode when you press the menu button next to the top right corner of the LCD; you use this same button to select menu options. I then had the idea to do it for Juniper switches. Just got an EX4200 and turned it on. error: configuration database locked by: abc terminal u0 (pid 948) on since 2012-05-22 10:01:38 HKT. The problem is tha it has a configuration on it and i have no usernames/passwords. Modification History 2024-03-27 : Article Created Related Information Juniper Support Portal. If I try logging in as root via J-web, I always get the incorrect username/password reply even though I am typing it correctly. 07-JNPR-3. Symptoms. Reset SSG140 to Factory Defaults without Physical Access. Reverting to the Default Factory Configuration for the EX Series Switch. being deleted, my preferred method to reset is to run Luckily, he hit record long enough to show us how he was able to reset it back to factory settings. net)I got my hands on another EX4200 which boots up perfectly ok. Reverting to the Factory-Default Configuration Using the Factory Reset/Mode button EX2300, EX3400, and EX4300-48MP Switches. ------------------------------------------- 1. better if you have configuration backup. Use the RESET CONFIG button to return the router to either the rescue configuration or the factory default configuration. The switch transitions into factory-default configuration and the console displays committing factory default configuration. 182 Each EX Series switch is programmed with a factory default configuration that contains the values set for each configuration parameter when the switch is shipped. Printable View « Go BackGo Back [SRX] Getting Started - Factory Reset. With virtual chassis technology (13 pages) Switch Juniper EX2200 Hardware Manual. mebyogbvpjratsibgxxyvcfdracknphgwfsjmpujeksvlpqrqxtmypnnmwipdjcdnymulwmxc